Skip to content

Industry

Invar Machining for Scientific Instruments, Labs and Accelerator Facilities

From university sample stages to accelerator alignment fixtures, we quote your Invar, Kovar or Alloy 42 RFQ as finished parts and place the work with a partner shop, and you deal with one contact.

1.2 to 1.6 ppm/°CTypical Invar 36 CTE near room temperature, versus about 23.5 for aluminum
0.3 to 0.6 ppm/°CTypical Super Invar CTE for the tightest alignment and calibration hardware
One itemised quotePartner shops price your drawing and you receive one quote for the finished parts
24 business hoursTypical response time on a submitted RFQ

Why Scientific Instruments & Research Labs programs specify these alloys

Research and instrument hardware asks a mount, a fixture or a bench to hold its position through a temperature swing that would be irrelevant on a general mechanical part but directly corrupts an alignment, a wavelength calibration or a beamline survey. Invar 36 and Super Invar reduce that thermal contribution at the material level, before any active compensation or re-survey is applied.

This buyer group ranges from a single postdoc ordering one custom fixture on a grant-funded purchase order to an accelerator facility ordering dozens of identical alignment plates for a beamline upgrade, and from an instrument manufacturer running a production line to a beamline group specifying leak-tight vacuum hardware. Each has different quantity, documentation and timeline realities, covered in our guides below.

Where Scientific Instruments & Research Labs uses Invar, Kovar and Alloy 42

Accelerator and beamline alignment

Magnet mounting plates, fiducial fixtures and reference structures that hold survey position between re-alignments.

Spectrometers and analytical instruments

Grating mounts, monochromator arms and detector rails where thermal drift shows up as calibration error.

Vacuum chambers and beamline hardware

Flanges, bellows interfaces and internal mounts that must seal reliably and hold position through bakeout cycles.

Custom research instrument fixtures

One-off or low-quantity parts for university and national lab instruments, often from informal drawings.

What to put on the RFQ, and what to vet in a supplier

We quote the finished parts and answer for them. Your program still sets its own qualification rules, so state them on the RFQ. These lines get you a quote that covers them and a shop that can answer the qualification questions your program asks.

  1. State the alloy and its ASTM spec explicitly, not just "Invar" or "low expansion metal".

  2. Flag which dimensions or features are actually alignment- or calibration-critical.

  3. Give your real operating temperature range and, for vacuum hardware, the bakeout profile.

  4. State quantity now and expected quantity over the life of the program or facility.

  5. Note any export control, NDA or facility security requirement upfront.

  6. Give your real need date and the reason for it (beamtime, grant deadline, production schedule).

Scientific Instruments & Research Labs guides

All guides

Alloy pages: Invar 36 machining, Super Invar machining, Kovar machining, Alloy 42 machining. Spec numbers and CTE by temperature band on the Invar specs reference.

Have a drawing ready?

Send the short version now. We will ask for anything missing. For full details up front use the full RFQ form. Reply within 24 business hours.

Your files go only to the partner shops we ask to price the part. Ask for an NDA and nothing is shared until it is signed.

STEP, IGES, PDF, DWG or DXF. Can't upload from your phone? Email the files to sales@invarmachining.com after you send this form.
Reply within 24 business hours.

Questions from Scientific Instruments & Research Labs buyers

Something else? Email .

How do labs and accelerator facilities order Invar parts?

You send an RFQ with your drawing, and we quote the finished parts and place the work with a partner shop that machines these alloys. You deal with us.

Are your partner shops certified for aerospace, nuclear or national lab work?

We do not hold or claim any certification ourselves. If your program requires ISO 9001, AS9100, a security clearance or a specific qualification, state it on the RFQ and we place the work with a shop that can show it. Ask for the certificate before you order.

We only need one custom part for a university lab instrument. Is that a normal request?

Yes. Single-part and low-quantity orders are common in this category. Expect the quote to reflect one-off setup cost rather than a production per-part price.

Can a shop quote from an informal sketch instead of a formal drawing?

Often yes, if the RFQ fills the gaps in words: material spec, which dimensions matter, tolerance intent and quantity. See our research lab custom machining guide for how to write that RFQ.

How is this different from your aerospace or semiconductor equipment coverage?

Those pages cover flight structures and fab-floor metrology equipment. This one covers accelerator, beamline, spectrometer and general research-instrument hardware, a distinct buyer group with its own quantity and procurement patterns.

Get a quote